Product

Projects

Electrical Components for Solar PV, Battery Energy Storage

AC Isolator Panel Mounting 800V 16A-125A

Product Benefits 

  • Add-on Auxiliary Contacts
  • Terminal cover
  • Side Mount Add-on Fourth Pole
  • Switch body
  • Rotating Handle
Download DatasheetRequest A Quote

Description

What are the Different Types of Electrical Isolator Switches?

Types of isolator switches include fused and non-fused. Fused isolator switches come as single-phase and three-phase devices. Isolator switches can also have different pole configurations: single-pole, double-pole and 4-pole.

01 Add-on Auxiliary Contacts

The isolating switch adopts the same auxiliary contact, and the auxiliary contact and the main pole of the switch act at the same time. A normally open contact with pre-disconnect function can be provided as required.

The isolation switch can be installed with up to four auxiliary accessories (2 on the right, 2 on the left)

02 Terminal shrouds

The isolation switch terminal shroud has a simple appearance design, high-quality transparent PC material, flame-retardant, high strength, no color change after long-term use, high-quality waterproof and easy to install.

03  Side Mount Add-on Fourth Pole

Simultaneous or early contact operation of the fourth pole with respect to the switch disconnector poles.

04  Switch body

ONCCY switch adopts compression contact opening and closing technology, and has the function of complete disconnection indication. It is an isolator、a

breaker or a switch, and with inlerlock mechanism, it can be to an exchage switch.

05  Rotating Handle Parts

Rotating handle, with anti-misoperation padlock design to prevent misoperation, safe and reliable; using high-quality flame-retardant materials, insulation and impact resistance; elegant and stylish design, beautiful and durable.

06  Rod extension

High-carbon steel material, beautiful and corrosion-resistant; coupled with high- temperature treatment, even if sufficient pressure is applied, it can maintain good smoothness; the products are standardized, easy to assemble, low cost, corrosion resistant, and cost-effective.

07  Mechanical interlocking mechanism

The interior is made of high-conductivity nickel-phosphorus copper, which has good conductivity and longer service life. The shell is made of high-strength flame- retardant PC material, which is fire- resistant and flame-retardant, in one step!

 

Technical Data

No Description Code
1 Type of Switch disconnectors EAS80-
2 Installation Form DB:Rail mounting            DC:Door interlocked           ELA:Aluminum enclosure box

PM:Panel mounting          EL:Plastic enclosure box

3 Rated current(A) 16:16A          20:20A            25:25A            32:32A          40:40A          63:63A

80:80A          80H:100A       100:100A       125:125A

4 Knob Lock Nil:Without lock                           R:With lock
5 Poles    2P       3P         4P            6P               8P
6 Knob color Nil:Blue knob                                  BW:Black/white rotating handle G:Gray knob                               Optional with lock RY:Rotating red/yellow handle           BB:Rotating black/black handle

With lock                                         without lock

7 Inter lock mechanism IM2:sync                         IM31:normal close              IM32:normal open

 

Short circuit withstand current of fuse protection (kA rms expected value)

Fuse class 415V 16A 20A 25A 32A 40A 63A 80A 100A 125A
Rated conditional short-circuit current  

415V

 

10kA

 

15kA

 

20kA

Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s

 

Rated short-time withstand current

 

0.3S

 

2.5kA

 

3kA

 

5kA

Short circuit performance (unprotected)

 

Rated short-time withstand current

 

1S

 

1.0kA

 

1.5kA

 

2.5kA

 

Rated short circuit making capacity

 

0.8kA

 

1.4kA

 

2.1kA

Cable cross section 1.5~10mm² 2.5~35mm² 10~70mm²
Rated insulation voltage Ui 800V
 

Rated impulse withstand voltage Uimp

 

8kV

Mechanical Endurance 100000
Ambient Temperature Operating -25~+55°C                  Storage -40~+70°C

 

Short circuit withstand current of fuse protection (kA rms expected value)

Fuse class 415V 16A 20A 25A 32A 40A 63A 80A 100A 125A
Rated conditional short-circuit current  

415V

 

10kA

 

15kA

 

20kA

Short circuit withstand current of circuit breaker for protection, any circuit breaker that can trip within 0.3s

 

Rated short-time withstand current

 

0.3S

 

2.5kA

 

3kA

 

5kA

Short circuit performance (unprotected)

 

Rated short-time withstand current

 

1S

 

1.0kA

 

1.5kA

 

2.5kA

 

Rated short circuit making capacity

 

0.8kA

 

1.4kA

 

2.1kA

Cable cross section 1.5~10mm² 2.5~35mm² 10~70mm²
Rated insulation voltage Ui 800V
 

Rated impulse withstand voltage Uimp

 

8kV

Mechanical Endurance 100000
Ambient Temperature Operating -25~+55°C                  Storage -40~+70°C

 

 

About ONCCY

Leading Manufacturer Protects Solar Power Safety.

Send An Inquiry

footer